网站模板含数据库下载,汽车网站策划,58同城做网站推广好不好,丁香花影视大全今日家中忽然断电#xff0c;之后 ESXi 服务器就一直疯狂转#xff0c;连接显示器#xff0c;发现原来一直没有启动。停留在ESXi Loading module ipmi_si_drv 是ipmi_si_drv模块没有加载。于是各种找原因#xff0c;google#xff0c;看到了一个帖子如下#xff0c;需要关…今日家中忽然断电之后 ESXi 服务器就一直疯狂转连接显示器发现原来一直没有启动。停留在ESXi Loading module ipmi_si_drv 是ipmi_si_drv模块没有加载。于是各种找原因google看到了一个帖子如下需要关闭这个模块但是连服务器都连接不到啊Today, when I restart a failed server, stuck in Loading module ipmi_si_drv ... , about 30 minutes boot is completed.avoid-vmware-esxi-loading-module-ipmi_si_drvFirst try setting IPMI to Shared in BIOS, if the option is available. When booting your installation media, press Shift O to display the boot arguments and add noipmiEnabled to the boot arguments. Remember to do the same once the installation/upgrade is complete. Manually turn off or remove the module by turning the option VMkernel.Boot.ipmiEnabled off in vSphere or using the commands below:# Do a dry run first:esxcli software vib remove –dry-run –vibname ipmi-ipmi-si-drv# Remove the module:esxcli software vib remove –vibname ipmi-ipmi-si-drvor try the following command in an unsupported shell connection:esxcfg-module -d ipmi_si_drvThis disables the module although it still gets loaded.Use a -l argument to see what modules are enabled/loaded and check that your desired one is disabled. This appears to be persistent across a reboot.后来又搜索到了 HP iLO is not responding 这篇文章When during boot of an HP ProLiant server you see the “iLO2 not responding. System health monitoring has been disabled.” error message you need to restart the HP Integrated Lights-Out (iLO) component in the server.iLo is a small, always on computer with a web interface to monitor and manage the hardware of the HP ProLiant servers. You can monitor the temperature sensors, fan speeds, power usage, and you can turn on and off the server remotely. So if you accidentally shut down the server or the server loses power and does not start automatically you can push the virtual power button on the web interface and turn on the server as if you would stand in front of it.To restart iLO in the HP ProLiant server you have to completely discharge all electricity from the server.shut down the server,disconnect all power cords from the electrical outlets,remove all power supplies from the server (you need to disconnect the power cord from the power supply too to remove the power supply),press and hold the power button on the front of the server for 15-30 seconds,re-install the power supplies,connect the power cables to the power supplies,connect the power cables to the electrical outlets,momentarily press the power button on the front of the server to turn on the server.This power reset does not erase any information of the iLO configuration, just restarts it.On the power on screen you should see the usual messages from iLO.原来是因为断电之后iLO信息丢失导致无法启动iLO4iLO4 的提示信息为Warning iLO4 not responding解决方法要在 HP ProLiant 服务器中重新启动iLO必须完全从服务器中释放所有电量1、关闭服务器2、从电源插座上拔下电源线3、从服务器上卸下所有电源(您也需要断开电源线与电源的连接以取消电源)4、按住服务器正面的电源按钮15-30秒5、重新安装电源6、将电源线连接到电源7、将电源线连接到电源插座8、暂时按服务器正面的电源按钮打开服务器9、此电源复位不会清除iLO配置的任何信息只需重新启动它。之后一切恢复了前后使用了2小时希望可以为遇到同样问题的人带来帮助。